Powerpac Cummins Range

Cummins Powered Powerpac Generating Set

Westac PowerPac Cummins powered generating sets couple the rugged and well proven reliability of the world-renowned Cummins water-cooled diesel engines to high performance alternators. They are recommended for all types of residential, commercial and industrial applications, either as prime power sources or intermittent stand-by. They provide dependable, efficient power supply options across a wide range.

60Hz 3 Phase 1800 RPM

Model Engine Prime Standby Fuel Cons
KVA KW KVA KW
   
WPC35 4B3.3G1 41 32.8 45 36 9.7
WPC50 4B3.3G2 59 47.2 65 52 13.4
WPC60 4BT3.9G4 70 56 73.7 58.96 15
WPC85 6BT5.9G5 99 79.2 109 87.2 24
WPC100 6BT5.9G6 123 98.4 136 108.8 29
WPC135 6CT8.3G2 152 121.6 167 133.6 37
WPC185 6CTA8.3G2 208 166.4 222.5 178 48
WPC200 6CTAA8.3G1 233 186.4 258 206.4 52
WPC230 LTA10G2 245 196 283 226.4 58.4
WPC250 LTA10G1 281 224.8 312 249.6 59
WPC300 NT855G6 326 260.8 360 288 74
WPC320 NTA855G2 347 277.6 383 306.4 79
WPC350 NTA855G3 400 320 442 353.6 87
WPC415 NTA855G5 N/A N/A 502 401.6 110
WPC400 QSX15G5 449 359.2 494 395.2 97.6
WPC450 QSX15G7 508 406.4 563 450.4 108
WPC500 QSX15G9 550 440 625 500 117
WPC640 VTA28G5 681 544.8 750 600 154
WPC800 QSK23G2 870 696 968 774.4 176
WPC910 QSK23G3 917 733.6 1027 821.6 189
WPC1000 QST30G4 1155 924 1250 1000 240
WPC910K KTA38G3 1039 831.2 1125 900 217
WPC1200K KTA38G4 N/A N/A 1250 1000 245
WPC1250K KTA50G3 1338 1070.4 1595 1276 291
WPC1550K KTA50G9 1550 1240 1875 1500 330
WPC1775 QSK60G5 1775 1420 2200 1760 402
WPC2250 QSK60G6 2250 1800 2500 2000 466

Downloadable Data Sheet

Download PDF version of the data sheet
Download 60Hz Data Sheet

For your convenience we also provide a downloadable data sheet in PDF format. If you do not have suitable software for reading PDF files, Adobe Acrobat Reader is freely available from http://www.adobe.com

Notes

  1. Figures quoted are based on a power factor of 0.8.
  2. All ratings are in accordance with ISO8528-1 and ISO3046, BS5514 and DIN6271 conditions.
  3. All ratings quoted are based upon nominal 380V 3ph 50Hz and 220/440V 3ph 60Hz. Voltages outside these parameters may alter the quoted ratings.
  4. Ratings quoted are based on standard alternator. Customer preference may alter ratings to suit available frame sizes.
  5. Ratings based on Cummins supplied test data under NTP conditions. Please contact Westac Power to assess if any derate is required.
  6. Fuel consumption figures are in litres per hour at 100% prime load.
  7. All information given is for guidance only and subject to alteration without notice.