Powerpac John Deere Range

John Deere Powered Powerpac Generating Set

Westac PowerPac John Deere powered generating sets couple the rugged and well proven reliability of the world-renowned John Deere water-cooled diesel engines to high performance alternators. They are recommended for all types of residential, commercial and industrial applications, either as prime power sources or intermittent stand-by. They provide dependable, efficient power supply options across a wide range.

50Hz 3 Phase 1500 RPM

Model Engine Prime Standby Fuel Cons
KVA KW KVA KW
   
WPJD22 3029DF 22.5 18 N/A N/A 7
WPJD 30 3029DF 30 24 32.5 26 7
WPJD 40 4039DF 40 32 42 33.6 9
WPJD 60 4039TF 60 48 70 56 14.5
WPJD 80 4045TF 81 64.8 87.5 70 19.5
WPJD 100 4045HF 100 80 106 84.8 23
WPJD 120 6068TF 120 96 132 105.6 26
WPJD150 6068HF 154 123.2 170 136 33.5
WPJD180 6068HF 186 148.8 205 164 42
WPJD250 6081HF 250 200 275 220 54
WPJD300 6125HF 300 240 N/A N/A TBC
WPJD350 6125HF 350 280 N/A N/A TBC
WPJD400 6125HF 392 313.6 415 332 TBC

Downloadable Data Sheet

Download PDF version of the data sheet
Download 50/60Hz Data Sheet

For your convenience we also provide a downloadable data sheet in PDF format. If you do not have suitable software for reading PDF files, Adobe Acrobat Reader is freely available from http://www.adobe.com

Notes

  1. Figures quoted are based on a power factor of 0.8.
  2. All ratings are in accordance with ISO8528-1 and ISO3046, BS5514 and DIN6271 conditions.
  3. All ratings quoted are based upon nominal 380V 3ph 50Hz and 220/440V 3ph 60Hz. Voltages outside these parameters may alter the quoted ratings.
  4. Ratings quoted are based on standard alternator. Customer preference may alter ratings to suit available frame sizes.
  5. Ratings based on John Deere supplied test data under NTP conditions. Please contact Westac Power to assess if any derate is required.
  6. Fuel consumption figures are in litres per hour at 100% prime load.
  7. All information given is for guidance only and subject to alteration without notice.