Powerpac Scania Range

Scania Powered Powerpac Generating Set

Westac PowerPac Scania powered generating sets couple the rugged and well proven reliability of the world-renowned Cummins water-cooled diesel engines to high performance alternators. They are recommended for all types of residential, commercial and industrial applications, either as prime power sources or intermittent stand-by. They provide dependable, efficient power supply options across a wide range.

60Hz 3 Phase 1800 RPM

Model Engine Prime Standby Fuel Cons
KVA KW KVA KW
   
WPS160 D9-92/10-22 167.5 134 188 150.4 32.6
WPS170 D9-92/10-21 190 152 216 172.8 36.8
WPS200 D9-92/10-20 238 190.4 258 206.4 46.1
WPS250 DC9-49/10-23 280 224 300 240 52.3
WPS280 DC9-50/10-26 300 240 320 256 56.6
WPS300 DC12-54/10-80 341 272.8 374 299.2 64.1
WPS330 DC12-54/10-81 350 280 383.5 306.8 65.1
WPS350 DC12-54/10-82 382 305.6 418.5 334.8 71.4
WPS380 DC12-54/10-83 393 314.4 417.5 334 74.2
WPS400 DC12-54/10-84 438 350.4 480 384 83.9
WPS401 DC16-43A/10-20 436 348.8 478 382.4 82.3
WPS450 DC16-43A/10-21 456 364.8 500 400 82.5
WPS500 DC16-43A/10-22 480 384 530 424 87.9

Downloadable Data Sheet

Download PDF version of the data sheet
Download 50/60Hz Data Sheet

For your convenience we also provide a downloadable data sheet in PDF format. If you do not have suitable software for reading PDF files, Adobe Acrobat Reader is freely available from http://www.adobe.com

Notes

  1. Figures quoted are based on a power factor of 0.8.
  2. All ratings are in accordance with ISO8528-1 and ISO3046, BS5514 and DIN6271 conditions.
  3. All ratings quoted are based upon nominal 380V 3ph 50Hz and 220/440V 3ph 60Hz. Voltages outside these parameters may alter the quoted ratings.
  4. Ratings quoted are based on standard alternator. Customer preference may alter ratings to suit available frame sizes.
  5. Ratings based on Scania supplied test data under NTP conditions. Please contact Westac Power to assess if any derate is required.
  6. Fuel consumption figures are in litres per hour at 100% prime load.
  7. All information given is for guidance only and subject to alteration without notice.